Industry 04 · Industrial process plant
Vessel resistance to dust explosion
We surveyed an existing dust-filtration vessel, modelled it under explosion loading and proposed strengthening.
Modelled peak von Mises stress: 84.8 MPa existing to about 18.7 MPa with proposed strengthening See both stress plots
- Sector
- Industrial process plant
- Project nature
- Dust explosion & filtration plant design
- Client
- ConfidentialA UK industrial process-plant operator
- Services
- Site inspection & vessel structural survey
- Dust deflagration desk study
- Structural analysis of existing structure
- Strengthening proposal
01 · Survey
Site inspection and vessel structural survey
The work started at the vessel itself. We inspected it on site and surveyed its structure, and the surveyed geometry became the basis of the analysis model: a 1.50 m square plan, the top at level +2.40 and a hopper below.
No material information existed for the vessel, so the steel was assumed to be grade S235.
- Plan
- 1.50 m × 1.50 m
- Top level
- +2.40
- Steel (assumed)
- S235
- Yield strength fy
- 235 MPa
- Ultimate strength fu
- 360 MPa
- Modulus E
- 205 GPa
Values from the calculation extract.

02 · Desk study
Dust deflagration desk study
The desk study assessed whether protection means were required. It worked from the properties of the dust — minimum ignition energy (MIE), ignition temperature, maximum explosion pressure Pmax, the Kst value and the dust class, St1 — and from BS EN 14491, the dust explosion venting standard.
Dust properties and standard
- Pmax
- 8.4 bar
- Kst
- 101 bar·m/s
- Dust class
- St1
- Venting standard
- BS EN 14491
Values from the calculation extract.
03 · Analysis
Analysis of the existing vessel
The explosion was treated as an accidental load combination, with all partial factors taken as 1.0. The existing structure was analysed under that combination.
The structural checks used the Eurocodes with the UK National Annex: BS EN 1990, BS EN 1991-1-1, BS EN 1993-1-1 and BS EN 1993-1-8.
Existing vessel · model results
- Peak von Mises stress, plain material
- 84.8 MPa
- Peak stress at welds
- 45.9 MPa
- Load combination
- Accidental
- Partial factors
- All 1.0
Values from the calculation extract.
See the stress plot in the comparison04 · Proposal
Strengthening proposal
The proposal adds 50×6 plates to the vessel, in steel of grade S275 as a minimum. The plates are fixed with fillet welds of minimum 3.5 mm throat, staggered 200-100-200-100-100.
- Plates
- 50×6
- Plate steel
- S275 minimum
- Fillet weld throat
- 3.5 mm minimum
- Weld stagger
- 200-100-200-100-100
- Modelled peak von Mises stress, strengthened
- about 18.7 MPa
Values from the calculation extract.


Before and after
Existing and strengthened, side by side.
The same vessel under the same accidental load combination, without and with the proposed plates.


Read the scales, not the colours. Both plots use the same colour ramp, but each has its own scale: the darkest red is 84.80 MPa on the existing vessel and 18.74 MPa on the strengthened one, so the same colour does not mean the same stress. Both show the accidental load combination with all partial factors 1.0. Values from the calculation extract.