Industry 04 · Industrial process plant

Vessel resistance to dust explosion

We surveyed an existing dust-filtration vessel, modelled it under explosion loading and proposed strengthening.

Modelled peak von Mises stress: 84.8 MPa existing to about 18.7 MPa with proposed strengthening See both stress plots
Dust-filtration vessel on an industrial floor: a square white vessel on a support frame with a hopper below, ducting above, an open access door and yellow safety rails in front. Enlarge
Fig. 1 The vessel as inspected on site.
Sector
Industrial process plant
Project nature
Dust explosion & filtration plant design
Client
ConfidentialA UK industrial process-plant operator
Services
  • Site inspection & vessel structural survey
  • Dust deflagration desk study
  • Structural analysis of existing structure
  • Strengthening proposal

01 · Survey

Site inspection and vessel structural survey

The work started at the vessel itself. We inspected it on site and surveyed its structure, and the surveyed geometry became the basis of the analysis model: a 1.50 m square plan, the top at level +2.40 and a hopper below.

No material information existed for the vessel, so the steel was assumed to be grade S235.

Plan
1.50 m × 1.50 m
Top level
+2.40
Steel (assumed)
S235
Yield strength fy
235 MPa
Ultimate strength fu
360 MPa
Modulus E
205 GPa

Values from the calculation extract.

Three-dimensional model of the vessel as surveyed: a box 1.50 m square on plan with its top at level +2.40 and a tapering hopper beneath. Fig. 2Enlarge
Vessel geometry as surveyed.

02 · Desk study

Dust deflagration desk study

The desk study assessed whether protection means were required. It worked from the properties of the dust — minimum ignition energy (MIE), ignition temperature, maximum explosion pressure Pmax, the Kst value and the dust class, St1 — and from BS EN 14491, the dust explosion venting standard.

Dust properties and standard

Pmax
8.4 bar
Kst
101 bar·m/s
Dust class
St1
Venting standard
BS EN 14491

Values from the calculation extract.

03 · Analysis

Analysis of the existing vessel

The explosion was treated as an accidental load combination, with all partial factors taken as 1.0. The existing structure was analysed under that combination.

The structural checks used the Eurocodes with the UK National Annex: BS EN 1990, BS EN 1991-1-1, BS EN 1993-1-1 and BS EN 1993-1-8.

Existing vessel · model results

Peak von Mises stress, plain material
84.8 MPa
Peak stress at welds
45.9 MPa
Load combination
Accidental
Partial factors
All 1.0

Values from the calculation extract.

See the stress plot in the comparison

04 · Proposal

Strengthening proposal

The proposal adds 50×6 plates to the vessel, in steel of grade S275 as a minimum. The plates are fixed with fillet welds of minimum 3.5 mm throat, staggered 200-100-200-100-100.

Plates
50×6
Plate steel
S275 minimum
Fillet weld throat
3.5 mm minimum
Weld stagger
200-100-200-100-100
Modelled peak von Mises stress, strengthened
about 18.7 MPa

Values from the calculation extract.

Three-dimensional model of the vessel seen from above, with the proposed strengthening plates forming a grid over the roof and walls. Fig. 3Enlarge
Proposed strengthening, top view.
Three-dimensional model of the vessel seen from below, with the proposed strengthening plates continuing down the hopper faces. Fig. 4Enlarge
Proposed strengthening, bottom view.

Before and after

Existing and strengthened, side by side.

The same vessel under the same accidental load combination, without and with the proposed plates.

Existing vessel84.8 MPaPeak von Mises stress, plain material
Von Mises stress plot of the existing vessel; its colour scale runs from 0.05 to 84.80 MPa. Fig. 5Enlarge
Plot scale0.0584.80 MPa
Strengthened vesselabout 18.7 MPaPeak von Mises stress on the colour scale
Von Mises stress plot of the strengthened vessel with the plate grid in place; its colour scale runs from 0.0 to 18.74 MPa. Fig. 6Enlarge
Plot scale0.018.74 MPa

Read the scales, not the colours. Both plots use the same colour ramp, but each has its own scale: the darkest red is 84.80 MPa on the existing vessel and 18.74 MPa on the strengthened one, so the same colour does not mean the same stress. Both show the accidental load combination with all partial factors 1.0. Values from the calculation extract.

Have a vessel or structure that needs checking?